Apartment settings for Rubetek intercoms
You have the flexibility to configure settings at two levels: general settings applicable to all apartments, and individual settings specific to each apartment. The Settings button is available to manage all the apartments only if a range of apartments is specified.
When changing the general settings, all individual settings remain unchanged.
The set of settings depends on the type of connection.
The system-wide audio settings for the intercom panel:
Automatic adjustment of the microphone volume.
Active noise reduction.
Adjustment of the speaker volume on the intercom panel during conversation.
Adjustment of the speaker volume on the subscriber device during conversation.
Intercom panel audio processing mode during conversation:
The standard environment (only voice).
The environment with background music.
The environment with significant background noise.
Noise reduction on the intercom panel:
Off.
Automatic noise reduction.
Enhanced noise reduction.
Manual noise reduction.
Service audio settings for the intercom panel:
Key press volume.
RTSP audio settings for the intercom panel:
Microphone sensitivity.
SIP audio settings for the intercom panel:
The speaker volume.
Microphone sensitivity.
Resistance:
Voltage of the analog line at idle, V.
Voltage of the analog line when the handset is lifted, V.
Voltage of the analog line when the button is pressed, V.
Analog audio settings for the intercom panel:
Proxying, handset speaker volume.
Handset speaker volume during conversation.
Additionally:
Ignore custom apartment settings.
Availability of settings
The following settings are available with regard to the type of connection:
Resistance
| Matrix-switching | Fixed | Smart | Combined 1 | Combined 2 |
---|---|---|---|---|---|
Voltage of the analog line at idle, V. | |||||
Voltage of the analog line when the handset is lifted, V. | |||||
Voltage of the analog line when the button is pressed, V. |
Audio volume settings
Matrix-switching | Fixed | Smart | Combined 1 | Combined 2 | |
The system-wide intercom panel audio settings (including SIP and Analog): | |||||
Turn on and off automatic volume adjustment of the microphone on the intercom entry panel. By default, the setting is off. This parameter functions in the following way: if a visitor speaks very loudly or quietly into the intercom panel, the panel will automatically adjust the volume accordingly, making it quieter or louder. | |||||
Turn on and off the active noise reduction. By default, the setting is off. Intercom panel noise cancellation controls the audibility of background noise on client analog handsets or SIP-devices. | |||||
The speaker volume on the intercom panel during conversation. This system-wide parameter restricts the volume levels for intercom speakers set for the Speaker volume on the intercom panel and Speaker volume on the intercom panel during conversation using SIP. For example, if these parameters are set to 15 and the current one is set to 10, the actual volume level will be 10. | |||||
The speaker volume on the subscriber device during conversation. This system-wide parameter restricts the following parameters:
For example, if these parameters are set to 15 and the current one is set to 10, the actual volume level will be 10. | |||||
Intercom panel audio processing mode during conversation. The parameter specifies the environment where the intercom panel is located.
The default value is – 0. | |||||
Noise reduction on the intercom panel. This parameter is used to enable and disable a passive noise reduction mode on the intercom panel.
| |||||
Service audio settings for the intercom panel | |||||
Key press volume. | |||||
RTSP audio settings for the intercom panel. Used to connect an intercom camera. | |||||
Microphone sensitivity level on the intercom panel during RTSP connection. This parameter is applied to set up an audio volume on a camera that will be added as an intercom camera. | |||||
Analog audio settings for the intercom panel | |||||
Speaker volume on the intercom panel. | |||||
Speaker volume on the analog handset during conversation. | |||||
Enable and disable custom settings for analog handsets. When the value is true, the settings are applied to all apartments. When the value is false, settings for each apartment will be taken into consideration. | |||||
SIP audio settings for the intercom panel | |||||
Microphone sensitivity level on the intercom panel during conversation, using SIP. The parameter is used to manage the speaker audio level on SIP devices (a mobile phone, a landline phone) during a SIP call. | |||||
Speaker volume on the intercom panel during conversation, using SIP. The parameter is used to set the speaker volume on the intercom panel during a SIP call. |
The default values
Function | Value |
---|---|
Resistance | |
Value range | 0-100 |
Voltage of the analog line at idle, V. Should be less than other two below in the table. | 3,60 |
Voltage of the analog line when the handset is lifted, V. | 7,80 |
Voltage of the analog line when the button is pressed, V. | 9,60 |
Volume | |
Value range | 0-15 |
Speaker audio volume on the intercom panel | 15 |
Speaker volume on the subscriber device during conversation | 14 |
Intercom panel audio processing mode during conversation | 0 |
Noise reduction on the intercom panel | 0 |
Key press volume on the intercom panel | – |
Microphone sensitivity level on the intercom panel during RTSP connection | 14 |
Speaker volume on the intercom panel | 14 |
Speaker volume on the analog handset during conversation | 12 |
Enable and disable custom settings for analog handsets | false |
Microphone sensitivity level on the intercom panel during conversation, using SIP | 15 |
Speaker volume on the intercom panel during conversation, using SIP | 13 |