Select Add device to open the form for adding a new actuator device.
The process for adding a new device to the platform depend on the selected vendor:
ONVIF-compatible device with relay (alarm) outputs — a network device supporting ONVIF standards, equipped with outputs or built-in relays to control access mechanisms such as electric locks, barriers, and gates. Additional capabilities of ONVIF devices on the platform: an ONVIF-compatible device can do more than control access. If the device is an IP camera with an alarm output, it can function as both an actuator device and a video surveillance camera. A single camera can therefore control connected equipment—such as a lock, barrier, or gate—while also providing video surveillance.
When ONVIF is selected as the vendor, specify the following parameters in the add-device form:
-
Device type – populated automatically and cannot be edited.
-
Device name – a user-defined name for the device.
-
Vendor – select a vendor from the available options. Select ONVIF.
-
Model – model selection is not available for the ONVIF vendor.
-
Location (toggle) – links the actuator device to an access point. It is off by default. Turning it on displays additional fields:
-
Location (text field) – select the location through which the actuator device is added.
-
Access point (text field) – select the access point to link to the actuator device. The list includes access points eligible for adding an actuator device. The list includes access points that meet the following conditions:
-
The access point type supports connecting an actuator device.
-
No actuator devices are linked to access points of type Drive-in or Defined (Fixed).
-
-
-
Network settings. To edit network settings, turn on the Network settings toggle.
The Network settings toggle is available only when a location and an access point are selected.
Enabling Network settings displays additional fields. Completing these fields is optional at this stage and can be done later.
-
ONVIF client IP – the IP address of the camera's ONVIF service.
-
Port – the camera's ONVIF port.
-
ONVIF client login and Password – credentials of an ONVIF user configured in the camera's web interface.
Once all parameters are entered, select Add.
The system then automatically checks:
-
Whether the form fields are completed correctly.
-
When Network settings is on, the system checks:
-
Whether an actuator device exists with the specified IP address and port. If an actuator device with the same IP address is already connected to the platform, the system displays its name as a selectable link.
-
Whether the ONVIF protocol is enabled on the actuator device.
-
Whether an alarm output control service is available.
-
-
Whether an available license exists.
If validation succeeds:
-
When Network settings is on:
-
The system connects to the device using the ONVIF protocol.
-
A new actuator device is created on the platform with the Connected status.
-
The Settings tab of the actuator device details displays the current alarm output configuration state.
-
-
When Network settings is off:
-
A new actuator device is created on the platform with the Not connected status.
-
-
If a location and an access point are specified, the actuator device is linked to that access point.
-
A license with the Actuator device licensing parameter is counted as in use.
-
A notification confirms that the actuator device is created.
-
An event is created.
If the ONVIF device is a surveillance camera added to the platform and connected via the ONVIF protocol, the following connection scenarios apply:
-
No surveillance camera with the specified IP address exists on the platform:
-
A new actuator device is created.
-
-
A camera with the specified IP address is found and is connected using the ONVIF protocol:
-
In that camera's detail card, the ONVIF settings tab displays the enabled Camera alarm output service in read-only mode.
-
A new actuator device is created.
-
-
A camera with the specified IP address is found and is connected using the RTSP protocol:
-
A new actuator device is created.
-
The system then opens the actuator device detail card.
A new actuator device can also be added and linked to an access point from the following system section:
Platform tree > location containing access points > Access control > access point details > Devices tab.