Settings. NetPing actuator device

The Settings tab manages network connection parameters for the controller. It contains two sections: Network settings and Alarm output.

Network settings

This section contains the controller connection settings.

The following parameters are displayed:

  • Connection status – the current connection status of the device: Connected or Not connected.

  • Device IP – the controller's IP address.

  • Port – the controller's port.

  • Login and Password – credentials of a user account configured in the controller's web interface.

  • The Connect button – displayed when no connection is established. Once the connection succeeds, the button changes to Disconnect and can be used to terminate the connection.

Connect an actuator device

If network settings aren't configured and the device isn't connected during device setup, the connection can be established later on the Settings tab.

Complete the fields in Network settings and select Connect device.

The system checks:

  • Whether the fields are completed correctly.

  • Whether an actuator device is already connected using the specified IP address and port.

  • Whether the device being connected is a NetPing controller.

The system then connects to the actuator device.

The following actions occur:

  • The actuator device detail card displays the Connected status.

  • The current alarm output configuration is displayed.

  • A notification confirms that the actuator device is connected.

  • A Connect actuator device event is created under Devices > Actuator devices > actuator device detail card > User actions tab.

If an actuator device with the specified IP address and port already exists, the system displays its name as a link to its device detail card.

Disconnect an actuator device

To disconnect the actuator device, select Disconnect. This triggers the following actions:

  1. The connection status changes to Not connected.

  2. The Disconnect button remains disabled until the system receives confirmation that the device is disconnected.

  3. The button label changes to Connect device.

  4. The data in the Alarm output section is cleared.

  5. The fields in Network settings retain their values.

  6. A Disconnect actuator device event is created under Devices > Actuator devices > actuator device detail card > User actions tab.

Discrete output

This section displays the controller's status and provides controls for operating it. All controls are available only when a connection to the controller is established.

  • Output state – the current output state in real time: Open or Closed.

  • Number of activations – the number of times the output has been activated.

  • Normal state – the state to which the controller returns after activation in Pulse (Monostable) mode: Open or Closed. This toggle is unavailable in Continuous mode.

  • Operating mode – displays the modes supported by the controller:

    • Pulse (Monostable) – the output automatically returns to its normal state after a specified interval. Selecting this mode enables the Pulse duration field for setting the interval.

    • Continuous (Bistable) – the controller output remains in the selected state until the next command.

Open once / Close once button – activates the output manually. The button label depends on the current output status and selected operating mode. Selecting the button has the following effects:

  • In Pulse (Monostable) mode:

    • Open once (available when the output status and normal state are both Closed) – changes the output status to Open. The button is disabled for the interval specified in Pulse duration. Once the interval ends, the output automatically returns to Closed and the button is enabled again.

    • Close once (available when the output status and normal state are both Open) – changes the output status to Closed. The button is disabled for the interval specified in Pulse duration. Once the interval ends, the output automatically returns to Open and the button is enabled again.

  • In Continuous (Bistable) mode:

    • Open once (available when the output status is Closed) – changes the output status to Open and the button label to Close once. The output remains Open until Close once is selected.

    • Close once (available when the output status is Open) – changes the output status to Closed and the button label to Open once. The output remains Closed until Open once is selected.

  • The Save button – saves the settings.