26.09 26.06 26.05 25.12
26.09 26.06 26.05 25.12 Russian English

Settings. ONVIF actuator device

The Settings tab manages network connection settings for an ONVIF device with the Alarm OUT hardware function. It contains two sections: Network settings and Alarm OUT.

Network settings

This section contains the connection settings for the ONVIF device.

The following settings are displayed:

  • Connection status – the current device connection status: Connected or Not connected.

  • ONVIF client IP – the IP address of the camera's ONVIF service.

  • Port – the ONVIF camera port.

  • ONVIF client login and Password – credentials for the ONVIF user configured in the camera's web interface.

  • Connect button – displayed when no connection is established. Once connected, the button changes to Disconnect and can be used to terminate the connection.

Connect an actuator device

If network settings are not configured and the connection is not established when the actuator device is added, the device can be connected from the Settings tab.

Complete the fields under Network settings and select Connect device.

The system checks:

  • Whether the fields are completed correctly.

  • Whether an actuator device exists at the specified IP address.

  • Whether ONVIF is enabled on the actuator device.

  • Whether an alarm output control service is available.

The system then connects to the actuator device using ONVIF:

  • If the platform detects a camera with the same IP address and port that is connected using ONVIF, the Camera alarm output setting is displayed as enabled and read-only on the camera detail card's ONVIF settings tab.

  • If the platform detects a camera with the same IP address that is connected using RTSP, the system establishes an ONVIF connection to the actuator device.

  • If no camera is detected on the platform, the system establishes an ONVIF connection to the actuator device.

The following changes occur:

  • The actuator device detail card displays the Connected status.

  • The current alarm output configuration status is displayed.

  • A notification confirms that the actuator device is connected.

  • A Connect actuator device event is created under Devices > Actuator devices > actuator device detail card > User actions tab.

Disconnect an actuator device

To disconnect the actuator device, select Disconnect. This triggers the following actions:

  1. The connection status changes to Not connected.

  2. The Disconnect button remains disabled until the system receives confirmation that the device has been disconnected successfully.

  3. The button label changes to Connect device.

  4. The data in the Alarm OUT section is cleared.

  5. The fields under Network settings retain their values.

  6. A Disconnect actuator device event is created under Devices > Actuator devices > actuator device detail card > User actions tab.

  7. If the ONVIF device is a camera added to the platform and connected using ONVIF, the Camera alarm output setting is no longer displayed on the camera detail card's ONVIF settings tab.

Alarm OUT

This section displays the actuator device's alarm output status and provides controls for the function. All controls are available only when a connection to the ONVIF device is established.

  • If the ONVIF device is a camera added to the platform, its name is displayed as a link. Selecting it opens the ONVIF settings tab on the camera detail card.

  • Alarm output name – the name retrieved from the device configuration.

  • Normal state – the state to which the device returns after activation in pulse mode. This value is configured on the ONVIF device and cannot be edited here.

  • Output status – the current alarm output state in real time: Open or Closed. The value updates automatically when the output state changes.

  • Operating mode – displays the modes supported by the ONVIF device:

    • Pulse (Monostable) – the actuator device automatically returns to its normal state after the configured interval. Selecting this mode enables the Pulse duration field, which specifies how long the alarm output remains Open after the actuator device is activated. The list contains values configured on the ONVIF device.

    • Continuous (Bistable) – the actuator device remains in the selected state until another command is issued.

  • Open once button – manually activates the alarm output once. Its label depends on the output status: Open once when the output is Closed, or Close once when it is Open. Selecting the button has the following effects:

    • In Pulse (Monostable) mode, the output automatically returns to the Normal state when the configured pulse duration expires.

    • In Continuous (Bistable) mode, the output remains in its current state until another open or close command is sent.

  • Save button – saves the settings.