While specific management features are vendor-dependent, this section focuses on the base setup and universal functions common to all supported hardware from within the General data tab.
Compatible vendors. We continuously update our list of supported hardware. For the most current list of compatible intercom vendors, please reach out via our Contact Page.
Vendor-specific documentation for advanced integration and management is available upon request via our Contact Page.
General settings
The settings are organized into several sections.
Basic information
This section contains the following fields:
-
Name – the intercom name.
-
Entrance type:
-
Main entrance
-
Additional entrance
-
Gate. See the detailed description below.
-
-
Entrance.
-
Entrance name.
If the intercom isn't linked to an access point, only the intercom name can be edited. The Go to access point link is displayed. Selecting it opens the Access point tab.
Door opening settings
-
Door opening time, sec – the time the door remains open when opened from an analog handset, a landline phone, or the mobile app.
-
Door opening methods – selects the available door opening methods. The Apartments tab provides individual toggles for each user. Settings on the current tab apply to all users added to all apartments of this intercom.
-
Open the door with a chip key. Enabled by default. Disabling it makes all intercom keys inactive. Keys can still be added, deleted, assigned to users, and managed in other ways.
-
Open the door with a temporary code. Enabled by default. Disabling it:
-
Hides the Temporary codes tab.
-
Hides the Visitors tab in the Intercoms section of the mobile app.
-
Deletes all existing temporary codes.
-
The codes aren't restored when the method is enabled again.
-
-
Open the door from the mobile app. Enabled by default. Disabling it makes the following changes in the Intercoms section of the mobile app:
-
Hides the door opening button.
-
Disables guest link creation on the Links tab.
-
-
Open the door using facial recognition. Disabled by default. Enabling it:
-
Enables automatic door opening through facial recognition.
-
Displays the Analytics tab for uploading reference photos for automatic door opening through facial recognition.
-
Displays the Photos to open tab in the intercom settings of the mobile app. Users can upload photos for automatic door opening through facial recognition.
-
Displays the Analytics events subsection on the Events tab.
-
-
Call lines
Select the communication channels that receive calls from the intercom. At least one call line must be enabled:
-
Analog handset – intercom calls are received on the analog handset installed in the apartment.
-
Forward to SIP account – intercom calls are forwarded to the SIP account configured for the apartment.
-
Mobile app – intercom calls are received in the user's mobile app.
Restrict video viewing
These settings restrict users' access to video from the intercom cameras. The Apartments tab provides individual toggles for each user. Settings on the General settings tab apply to all users added to all apartments of this intercom.
-
Restrict live video viewing – restricts access to live video from the intercom camera.
-
Restrict archive video viewing – restricts access to archived video from the intercom camera. For events (answered and missed calls), archived video remains available from 15 seconds before to 30 seconds after the event.
Door control
-
Open door – opens the door for the duration specified in Door opening settings.
-
Open for a period – select how long the door remains open after selecting the button. Selecting Permanently keeps the door open until another value is selected.
-
Close door – closes the door.
Once changes are made, select Save to save them. This doesn't apply to functions in the Door control section.
Gate entrance type
The Gate entrance type is intended for an intercom panel installed at the entrance to a shared area, such as the courtyard of a residential complex. This panel can interact with intercoms at individual building entrances or sections.
Once Gate is selected as the entrance type and the changes are saved:
-
On the General settings tab:
-
The Entrance field becomes unavailable for editing.
-
Under Connection scheme, all three call lines are displayed as enabled and can't be changed. However, the Analog handset line isn't used for calls from a gate intercom. Calls use Forward to SIP and Mobile app.
-
The Door opening methods section is hidden. Available methods are described in the Gate documentation section.
-
The Restrict video viewing section is hidden. The restrictions are described in the Gate documentation section.
-
-
The Apartments tab is hidden. Apartments are configured in the detail cards of the entrance intercoms linked to the gate.
-
The Gate tab is displayed for managing links to entrance intercoms. The tab is described in the Gate documentation section.
Change the entrance type to Main or Additional
The entrance type of a gate intercom can be changed to Main or Additional.
If entrance intercoms are linked to the gate intercom, changing its entrance type displays a warning: Changing the entrance type will unlink all intercoms linked on the Gate tab from the current intercom.
Once the change is confirmed and the new entrance type is saved:
-
All linked entrance intercoms are unlinked.
-
Data synchronization with entrance intercoms stops.
-
Data and keys received from those intercoms are deleted.
-
The Gate tab is hidden.
-
The tabs and settings for the selected entrance type become available.