Compatible vendors. We continuously update our list of supported hardware. For the most current list of compatible intercom vendors, please reach out via our Contact Page.
Vendor-specific documentation for advanced integration and management is available upon request via our Contact Page.
The top of the page displays a panel with intercom details and management options:
The panel contains:
-
The intercom name. The entrance type is shown in parentheses.
-
The intercom UUID, with an option to copy the value to the clipboard.
-
Access point location – the full name of the access point's location in the platform tree. If the intercom isn't linked to an access point, the system displays a dash (-). Selecting the location opens its list of access points.
-
Number to dial at the gate – the number automatically assigned to an entrance intercom when it is added to a gate intercom. The number is used to select the entrance intercom when making a call from the gate intercom. It is generated automatically.
-
The entrance (if specified).
-
The intercom availability status: Online or Offline.
-
The connection transport type: HTTP or MQTT.
-
The synchronization status of the configured settings. The panel also shows the settings revision number. The Message queue tab provides a list of changes.
-
The vendor.
-
The intercom IP address.
-
The intercom MAC address.
-
The intercom serial number.
-
The button to return to the list of intercoms.
-
The button to restart the panel. The button is disabled if:
-
The intercom is offline.
-
The intercom isn't connected (no IP address has been assigned).
-
-
The button to turn the panel on or off (described below).
-
The button to replace the panel. The button is disabled if:
-
The intercom is offline.
-
The intercom isn't connected (no IP address has been assigned).
-
-
The button to delete the intercom.
The intercom settings are organized into several tabs.
Turn the panel on and off
When the panel is turned off, the intercom status changes to Disabled. The intercom remains in the list, but its functionality is limited in both the Administrator panel and the mobile app.
In the Administrator panel:
-
The system stops recording video feed to its archive from the intercom camera. The previously recorded archive remains available to view.
-
Camera live streaming is no longer available.
-
The Open the door using facial recognition option is paused. The video analytics stream gets the Paused status.
-
The system blocks changes to the intercom settings.
The following options remain available:
-
The intercom door can still be opened with physical keys.
-
The intercom door can still be opened with temporary codes created before the panel was turned off.
-
Calls from the intercom panel to an analog handset.
In the mobile app, the following options are disabled:
-
View video from the camera.
-
Add, edit, and delete photos.
-
Set the schedule.
-
Configure which device receives calls.
-
Add users.
The following options remain enabled:
-
View the history of calls.
-
View and filter the events.
-
Open the archive from an event.
-
View the added photos.
-
View the schedule.
-
View the visitors.